IP grade waterproof test method for SanAce cooling fan
- Categories:Technology
- Author:rain
- Origin:capital
- Time of issue:2022-12-09 15:17
- Views:
(Summary description)
IP grade waterproof test method for SanAce cooling fan
(Summary description)
- Categories:Technology
- Author:rain
- Origin:capital
- Time of issue:2022-12-09 15:17
- Views:
IP grade waterproof test method for SanAce cooling fan
IP protection grade is to grade electrical appliances according to their characteristics of dust and moisture prevention. The waterproof grade can be divided into 8 grades according to the waterproof effect, and the test methods of the 8 grades are as follows:,
⑴IPX 1
Method name: vertical drip test
Test equipment: drip test device
Sample placement: place the sample on the rotating sample table at 1r/min according to the normal working position of the sample, and the distance from the top of the sample to the dripping mouth shall not be greater than
Duration: 10 min
⑵IPX 2
Method name: inclined 15 ° drip test
Test equipment: drip test device
Specimen placement: make one surface of the specimen form a 15 ° angle with the vertical line, and the distance from the top of the specimen to the drip mouth shall not be greater than
Test conditions: water drop is
Duration: 4 × 2.5 min (10 min in total)
⑶IPX 3
Method name: water sprinkling test
Test method:
a。 Pendulum type water sprinkling test
Test equipment: swing tube water sprinkling and splashing test device
Sample placement: select a swing tube with an appropriate radius, make the height of the sample table at the position of the diameter of the swing tube, place the sample on the sample table, make the distance from its top to the sample spray nozzle not more than
Test conditions: the water flow is calculated according to the number of spray holes in the swing tube, and each hole is
Test time: continuous sprinkling for 10 min
b。 Sprinkler type water spraying test
Test equipment: hand-held water sprinkling test device
Specimen placement: make the parallel distance between the top of the test and the nozzle of the hand-held nozzle between
Test conditions: the baffle with counterweight shall be installed during the test, and the water flow is
Test time: 1 min per square meter (excluding the installation area) based on the surface area of the tested sample shell, at least 5 min
⑷IPX 4
Method name: water splash test
Test method:
a. Pendulum type water splash test
Test equipment and sample placement: the same as the above IPX 3 paragraph a;
Test conditions: except for the following conditions, they are the same as the above IPX 3 paragraph a; The water spraying area is the water spraying from the water spraying holes in the 90 ° arc segments on both sides of the midpoint of the swing pipe to the sample. The sample is placed in the center of the semicircle of the pendulum tube. The pendulum tube swings 180 ° along both sides of the vertical line, about 360 ° in total. Each swing (2 × 360 °) about 12s
Test time: the same as that of IPX 3 (a) (10 min).
b. Sprinkler type water splash test
Test equipment and sample placement: the same as the above IPX 3 paragraph b;
Test conditions: remove the baffle with counterweight installed on the equipment, and the rest are the same as the above IPX 3 (b);
Test time: The test time is the same as that of IPX 3 (b) above, that is, 1 min per square meter (excluding the installation area) based on the surface area of the tested sample shell, and at least 5 min
⑸IPX 5
Method name: Water spray test
Test equipment: inner diameter of nozzle nozzle is
Test conditions: make the distance between the test sample and the spray nozzle
Test time: 1 min per square meter (excluding the installation area) calculated according to the surface area of the tested sample shell, at least 3 min
⑹IPX 6
Method name: Strong water spray test;
Test equipment: inner diameter of spray nozzle is
Test conditions: make the distance between the test sample and the water spray nozzle
Test time: 1 min per square meter (excluding the installation area) calculated according to the surface area of the tested sample shell, at least 3 min
⑺IPX 7
Method name: Short time immersion test
Test equipment and test conditions: immersion tank. The size shall be such that the distance from the bottom of the sample to the water surface is at least
Test time: 30 min
⑻IPX 8
Method name: continuous diving test;
Test equipment, test conditions and test time: the severity shall be higher than IPX 7 through negotiation between the supplier and the buyer (the seller).
Capital Technology Co., Limited is the chief agent of SANYO DENKI, one of the leading enterprises of the cooling fan industry. We are a factory who also have our own independent brand CAPITAL product series. The main products are cooling fan, DC/AC fan, radiator, filter, reactor etc. We can provide customer with the most professional and perfect technical support, welcome to contact me at anytime at rainlee@szcpt.com.
Related Products
Copyright©2020 Capital Technology Co., Limited.