How to Read Specifications (DC fan) Sanace
- Categories:Technology
- Author:rain
- Origin:capital
- Time of issue:2021-06-01 11:51
- Views:
(Summary description)How to read the DC fan specifications? Please see below sanyodenki DC fan description:
How to Read Specifications (DC fan) Sanace
(Summary description)How to read the DC fan specifications? Please see below sanyodenki DC fan description:
- Categories:Technology
- Author:rain
- Origin:capital
- Time of issue:2021-06-01 11:51
- Views:
How to read the DC fan specifications? Please see below sanyodenki DC fan description:
Model No. | Rated Voltage | Operating voltage range | Rated current | Rated input | Rated speed | Max. airflow | Max static / pressure | SPL | Operating temperature | Expected life |
9GA0412G7001 | 12 | 7 to 13.8 | 0.17 | 2.04 | 13100 | 0.36 m³/12.7CFM | 192 Pa/0.77 inchH2O | 42 | -20 to +70 | 40000H/60°C (70000H/40°C) |
Rated voltage -- This is the necessary voltage to drive the fan. E.g.) 12 VDC, 24VDC,48VDC.
Operating voltage range -- The voltage range over which fan operation is guaranteed.
Rated current -- The current when the fan is operating at rated voltage (at free air).
Rated input -- The power value when the fan is operating at rated voltage (at free air).
Rated speed -- The speed when the fan is operating at rated voltage (at free air).
Max. airflow -- The maximum airflow that the fan can generate during rated operation (measured with our double chamber measuring device). Airflow is the volume of air generated by the fan per unit of time.
Max. static pressure -- The maximum static pressure value that the fan can produce during rated operation (measuerd with our double chamber measuring device). Static pressure indicates a fan's ability to move air against resistance due to the internal structure of the device to which the fan is installed.
SPL -- SPL stands for Sound Pressure Level. The noise level during the fan's rated operation. Please refer to the technical material section for the measurement method.
Operating temperature -- The temperture range over which fan operation is guaranteed (Non-condensing).
Expected life -- Service life hours that 90% of bearings will survive without failing when continuously operated at the rated voltage and 60ºC temperature. Expected life at 40ºC is for reference only.