Service Hotline
0755-27087416/18316996909
HOME
ABOUT US
Company Profile
Honor
Staff style
Factory environment
SANYODENKI
SANYO Fan
DC Fan
AC Fan
Reversible Flow Fan
Splash Proof Blower
G Proof Fan
Wide Temperature Range Fan
Cooling Fan Unit
Blower
Centrifugal Fan
Long Life Fan
Oil Proof Fan
Splash Proof Cenrtifugal Fan
Splash Proof Fan
ACDC Fan
PWM Controller
Airflow Tester
Finger guard
SANYO Servo Motor
Motion controller
Linear servo system
3-PHASE STEPPING SYSTEMS
2-PHASE STEPPING SYSTEMS
Linear actuator stepping motor
5-Phase Stepping Systems
Closed Loop Stepping Systems
DC Servo Systems
AC servo system spindle motor
AC Servo Systems
SANYO UPS
CAPITAL
DC Blower
EMI filter
Single phase, filters
3-phase, 1-stage EMI filters
3-phase+N line,3-stage EMI filters
DC filters
Military filters
Reactor
Sinusoidal filter
SOLUTIONS
Cooling solution
NEWS
Company news
Industry news
Technology
CONTACT US
Contacts
Message
CHINESE
What does DC fan mean? Detailed explanation of operating principle of SanAce DC fan
2022/11/21
What are the technical indicators of Sanyo cooling fan? Now let's analyze it together.
What are the technical indicators of Sanyo cooling fan? Now let's analyze it together. 1. Air volume. Air volume refers to the total amount of air discharged or inhaled by the cooling fan per minute. If it is calculated in cubic feet, the air volume unit is CFM; If measured in cubic meters, it is CMM. The unit of air volume often used by Sanyo cooling fan is CFM (about 0.028 cubic meters per minute). The air volume is an important indicator to measure the cooling capacity of the cooling fan. Obviously, the larger the air volume is, the higher the cooling capacity of Sanyo cooling fan is. This is because the heat capacity ratio of air is certain. The larger the air volume is, that is, the more air there is in a unit time, the more heat it takes away. Of course, under the same air volume, the heat dissipation effect is related to the wind flow mode. 2. Wind pressure. Air pressure and air volume are two relative concepts. Generally speaking, in order to design a fan with large air volume, it is necessary to sacrifice some air pressure under the consideration of cost saving by the manufacturer. If the cooling fan can drive a large amount of air flow, but the air pressure is small, The wind cannot blow to the bottom of the radiator (this is why some fans have high speed and large volume, but the heat dissipation effect is poor. On the contrary, high wind pressure often means that the air volume is small. There is not enough cold air to exchange heat with the radiator, which will also cause poor heat dissipation effect. 3. Fan speed. Fan speed refers to the number of revolutions of fan blades per minute, in rpm. Fan speed is determined by the number of turns of coils in the motor, working voltage, number of fan blades, inclination, height, diameter and bearing system. The speed is not necessarily related to the fan quality. The fan speed can be measured by internal speed signal or external measurement. With the change of application and ambient temperature, fans with different speeds are sometimes required to meet the demand. Some manufacturers have specially designed cooling fans with adjustable fan speed, which can be divided into manual and automatic ones. Manual is mainly used to enable users to obtain low noise at low speed in winter and good heat dissipation at high speed in summer. Generally, self-adjusting radiators are equipped with temperature control sensors, which can automatically control the fan speed according to the current working temperature, When the temperature is high, the speed will be increased; when the temperature is low, the speed will be reduced to achieve a dynamic balance, so as to maintain a good combination between wind noise and heat dissipation effect. 4. Fan noise. In addition to the heat dissipation effect, the noise of Sanyo cooling fan is also a common concern. Fan noise is the noise generated by the fan when it is working. It is affected by many factors, and the unit is decibel (dB). When measuring the fan noise, it needs to be conducted in an anechoic room with the noise less than 17dB, one meter away from the fan, and aligned with the air inlet of the fan along the direction of the fan axis. The A-weighted method is used to measure the fan noise. The spectral characteristics of the fan noise are also very important, Therefore, it is also necessary to record the noise frequency distribution of the fan with a spectrometer. Generally, the fan noise should be as small as possible, and there should be no abnormal sound. The noise of Sanyo cooling fan is related to friction and airflow. The higher the speed of Sanyo cooling fan, the greater the air volume, and the greater the noise. The vibration of the fan itself is also a factor that cannot be ignored. Of course, the vibration of high-quality fans will be very small, but the first two are difficult to overcome. To solve this problem, we can try to use larger fans. When the air volume is the same, The working noise of large fans at low speed is smaller than that of small fans at high speed. Another factor that we tend to ignore is the fan orientation. When the fan rotates at high speed, the shaft and bearing will collide with each other, so it is also a major source of fan noise. Capital Technology Co., Limited is the chief agent of SANYO DENKI, one of the leading enterprises of the cooling fan industry. We are a factory who also have our own independent brand CAPITAL product series. The main products are cooling fan, DC/AC fan, radiator, filter, reactor etc. We can provide customer with the most professional and perfect technical support, welcome to contact me at anytime at rainlee@szcpt.com.
2022/11/07
Special SanAce cooling fan for power supply 9GA0812P4H001
SANYO DENKI
2022/10/25
Model Selection of SanAce Silent Fan
2022/10/18
The cooling fan is divided into DC fan and AC fan
2022/10/09
Application case of 6015 oil proof cooling fan for servo driven DC fan
Application case of 6015 oil proof cooling fan for servo driven DC fan The servo driver is a controller used to control the servo motor, which is generally used in the fields of robots and industrial automation equipment. It controls the equipment through position, speed and torque to achieve high-precision positioning of the transmission system. With the high performance of product robots, the miniaturization of the servo driver and the emergence of high-performance products, which makes the semiconductor heating inside the servo driver increase, Therefore, it is necessary to improve the heat dissipation effect. A heat dissipation fan with high heat dissipation performance should be used. In addition, the use environment of the servo driver is diversified, and it is often used in harsh environments, greasy dirt and other special environments. Therefore, the heat dissipation fan should not only have high heat dissipation performance, but also have oil proof performance, and use oil proof heat dissipation fan The heat dissipation research and development project provides a professional heat dissipation fan scheme according to the diversified requirements of server application scenarios. It recommends the SanAce6015 DC fan 24V oil proof heat dissipation fan, which is 9WF0624H701. The oil proof heat dissipation fan can operate continuously for 40000 hours under the application scenario of 60 ℃. The fan is used for cooling the substrate in the servo driver; SanAce oil proof fan 9WF0624H701 recommends the following factors: 1. The oil proof fan 9WF0624H701 process is to cover the fan circuit board and coil with resin with good oil resistance, so that oil, water, dust, etc. will not enter the fan and cause damage under bad conditions; 2. The blade and frame of the oil proof cooling fan are made of chemically stable resin 3. Oil proof cooling fan To prevent oil stain and dust from jamming the fan blade, increase the spacing between the fan blade and the frame 4. SanAce oil proof fan has been running continuously for more than one month under the oil pollution environment, and there is no abnormality in the fan speed and sensor. Considering that the fan should be used in such a high humidity and high oil mist environment in the machine tool, Factory has conducted tests with several types of oil pollution. Ensure high quality and reliability of cooling fan 5. If the standard fan is used in the same environment, the oil stain invades the base plate and the winding part, causing corrosion and wire breakage. The ordinary fan will be damaged due to corrosion before its expected life when it is used in an oily environment. The SanAce oil proof fan can also be used normally in this harsh environment to ensure normal cooling performance of the equipment 6. The fan can be used normally in the environment with high indoor humidity, water, oil, etc. The setting place of the customer's equipment does not need to be specially designated. 7. The oil and dust are dried after long-term contact, and the dust is fixed on the fan, which extends the time when the fan blades are blocked, thus prolonging the service life of the equipment. Capital Technology Co., Limited is the chief agent of SANYO DENKI, one of the leading enterprises of the cooling fan industry. We are a factory who also have our own independent brand CAPITAL product series. The main products are cooling fan, DC/AC fan, radiator, filter, reactor etc. We can provide customer with the most professional and perfect technical support, welcome to contact me at anytime at rainlee@szcpt.com.
2022/09/26