Service Hotline
0755-27087416/18316996909
HOME
ABOUT US
Company Profile
Honor
Staff style
Factory environment
SANYODENKI
SANYO Fan
DC Fan
AC Fan
Reversible Flow Fan
Splash Proof Blower
G Proof Fan
Wide Temperature Range Fan
Cooling Fan Unit
Blower
Centrifugal Fan
Long Life Fan
Oil Proof Fan
Splash Proof Cenrtifugal Fan
Splash Proof Fan
ACDC Fan
PWM Controller
Airflow Tester
Finger guard
SANYO Servo Motor
Motion controller
Linear servo system
3-PHASE STEPPING SYSTEMS
2-PHASE STEPPING SYSTEMS
Linear actuator stepping motor
5-Phase Stepping Systems
Closed Loop Stepping Systems
DC Servo Systems
AC servo system spindle motor
AC Servo Systems
SANYO UPS
CAPITAL
DC Blower
EMI filter
Single phase, filters
3-phase, 1-stage EMI filters
3-phase+N line,3-stage EMI filters
DC filters
Military filters
Reactor
Sinusoidal filter
SOLUTIONS
Cooling solution
NEWS
Company news
Industry news
Technology
CONTACT US
Contacts
Message
CHINESE
08-29
Characteristics and Analysis of Cooling Fan Noise
The noise produced by a cooling fan is an inevitable byproduct of its operation, and its characteristics are closely related to factors such as the fan's structure, operating status, and environment. In-depth analysis of these characteristics not only helps us judge the working condition of the fan but also provides a basis for noise reduction design. The following explanations are divided into three aspects: the characteristic performance of the noise, the causes of its generation, and the analysis methods: I. Characteristic Performance of Cooling Fan Noise The noise of a cooling fan is not a pure tone with a single frequency but a superposition of multiple components, mainly having the following characteristics: 1. Frequency Characteristics Low-frequency noise: Generally refers to sounds with a frequency below 200Hz, mostly generated by mechanical vibrations of the fan (such as bearing friction, resonance caused by unbalanced fan blades). It is characterized by long propagation distance, strong penetration, and gives people a dull and oppressive feeling. Mid-frequency noise: With a frequency between 200Hz and 2000Hz, it mainly comes from the turbulent disturbance when the fan blades cut through the air. It is the main component of fan noise and sounds relatively "noisy". High-frequency noise: With a frequency above 2000Hz, it is mostly caused by airflow separation at the edge of the fan blades, high-frequency vibration of the motor, or friction in assembly gaps. It manifests as a sharp "hissing" or "buzzing" sound, which is highly irritating to the human ear. 2. Intensity Characteristics (Sound Pressure Level) The intensity of sound is measured by the sound pressure level (unit: decibel, dB). The sound pressure level of a fan is usually between 20dB (quiet environment) and 60dB (relatively noisy), which is directly related to the rotational speed: the higher the rotational speed, the faster the fan blades cut through the air, and the greater the sound pressure level (generally, for every 10% increase in rotational speed, the sound pressure level increases by about 2-3dB). 3. Time Characteristics Steady-state noise: When the fan is running normally, if the rotational speed is stable, the noise intensity and frequency remain basically unchanged (such as a cooling fan rotating at a constant speed), which is classified as steady-state noise. Unsteady noise: When the fan's rotational speed fluctuates (such as during the speed regulation process of an intelligent temperature-controlled fan), foreign objects adhere to the fan blades, or the bearings are worn, the noise will change over time, showing as sounds that are "fluctuating in volume" or "intermittent". II. Analysis of the Causes of Cooling Fan Noise The sources of fan noise can be divided into aerodynamic noise and mechanical noise: 1. Aerodynamic Noise (Main Source) Generated by the interaction between the fan blades and air, specifically including: Vortex noise: When the fan blades rotate, a boundary layer of airflow is formed on their surface. When the airflow separates at the edge of the fan blades, a large number of vortices are generated. The formation and collapse of these vortices cause air vibration, resulting in noise (the higher the rotational speed and the more irregular the shape of the fan blades, the more obvious the vortex noise). Rotational noise: The fan blades periodically cut through the air, causing periodic changes in air pressure, forming pulsed noise. The frequency is related to the number of fan blades and the rotational speed (formula: frequency = rotational speed × number of fan blades / 60. For example, a 4-blade fan with a rotational speed of 3000RPM has a frequency of 3000×4/60 = 200Hz). 2. Mechanical Noise Generated by the movement or vibration of the internal mechanical structure of the fan: Bearing noise: Sliding bearings (oil-containing bearings) produce relatively large friction noise, which will intensify as the service time increases (due to lubricating oil loss); ball bearings have relatively small friction noise, but improper assembly (such as excessive clearance) may produce "ball impact sound". Vibration noise: When the center of gravity of the fan blades does not coincide with the rotation axis (unbalanced), centrifugal force will be generated, causing the overall vibration of the fan, which in turn triggers resonance of the housing or mounting components, producing low-frequency noise; uneven clearance between the motor rotor and stator can also generate vibration noise due to fluctuations in electromagnetic force. Friction noise: Friction between the fan blades and the frame, wires, or other components, or irregular friction caused by dust adhering to the fan blades, will produce high-frequency abnormal sounds. III. Analysis Methods of Cooling Fan Noise Analyzing fan noise through professional means can locate the source of noise and optimize the design: 1. Subjective Evaluation Rel
08-26
What Are the Impacts of Fans on Power Supply Systems? What Are the Advantages of Sanyo SanAce Cooling Fans?
Cooling fans maintain stable temperatures in power supply systems through active heat dissipation. Their impacts on power supply systems need to be analyzed from multiple dimensions, including performance guarantee, reliability, energy consumption, and potential risks.
08-22
A Brief Discussion on Cooling Fans Used in New Energy Vehicles
Cooling fans are important components of the thermal management system in new energy vehicles. They are mainly used to dissipate heat from components such as batteries and motors, ensuring that these components operate within an appropriate temperature range, thus guaranteeing the vehicle's performance and service life.
08-19
What are the Advantages of Temperature-Controlled Fans?
Compared to traditional fixed-speed fans, temperature-controlled fans have significant advantages in performance, energy consumption, lifespan, and other aspects.
08-15
Common Faults and Solutions of Industrial Cooling Fans
Industrial cooling fans are prone to faults due to environmental factors, wear and tear, installation issues, etc., during long-term, high-load operation, which affects the heat dissipation efficiency of equipment and may even lead to equipment shutdown.
08-12
How to Determine if Sanyo Waterproof Fans Are Suitable for Use in Low-Temperature Environments?
Sanyo waterproof fans can generally operate normally in low-temperature environments. In general, Sanyo waterproof fans have a wide operating temperature range, with most models capable of stable operation within the range of -20°C to 70°C, such as the San Ace 9WFA0824G6001 oil-resistant fan and the 9WL0912P4H001 DC waterproof cooling fan, among others.